| Document Number | Revision | Title |
|---|---|---|
| KSC-DF-107 | D | TECHNICAL DOCUMENTATION STYLE GUIDE |
| KSC-E-165 | E | ELECTRICAL GROUND SUPPORT EQUIPMENT FABRICATION, SPECIFICATION FOR |
| KSC-E-166 | C | ELECTRICAL GROUND SUPPORT EQUIPMENT, INSTALLATION AND ASSEMBLY, SPECIFICATION FOR |
| KSC-F-124 | E | FITTINGS, FLARED TUBE, SPECIFICATION FOR |
| KSC-GP-425 | G | FLUID FITTING ENGINEERING STANDARDS |
| KSC-GP-435 | B, Change 3 | ENGINEERING DRAWING PRACTICES. VOLUME 2: FACILITIES (INCLUDES CHANGES 1-3, CHANGE 3 DATED 7/2/1999) |
| KSC-GP-435, VOLUME 1 | F, Change 2 | ENGINEERING DRAWING PRACTICES. VOLUME 1: AEROSPACE AND GROUND SUPPORT EQUIPMENT |
| KSC-S-126 | B | SEALING OF ELECTRICAL COMPONENTS, SPECIFICATION FOR |
| KSC-SO-S-9 | J | COMPRESSED GAS TRAILERS, RETEST AND REFURBISHMENT OF, SPECIFICATION FOR |
| KSC-SPEC-E-0012 | Baseline | HEAT AND BLAST PROTECTION COATING MATERIALS FOR ELECTRICAL CABLES, SPECIFICATION FOR |
| KSC-SPEC-E-0017 | C | ELECTRICAL POWER CABLES, INSTALLATION OF, SPECIFICATION FOR |
| KSC-SPEC-E-0018 | B | AC POWER WIRE, GENERAL PURPOSE, SINGLE CONDUCTOR, 600 VOLT, 60 HERTZ, PROCUREMENT OF, SPECIFICATION FOR |
| KSC-SPEC-E-0019 | B | AC POWER CABLE, GENERAL PURPOSE, MULTI-CONDUCTOR, 600 VOLT, 60 HERTZ, PROCUREMENT OF, SPECIFICATION FOR |
| KSC-SPEC-E-0020 | C | AC POWER CABLE, MINERAL INSULATED, 600 VOLT, 60 HERTZ, PROCUREMENT OF, SPECIFICATION FOR |
| KSC-SPEC-E-0021 | B | AC POWER CABLE, INTERLOCKED ARMORED, 600 VOLT, 60 HERTZ, PROCUREMENT OF, SPECIFICATION FOR |
| KSC-SPEC-E-0022 | B | AC POWER CABLE, 5,000 VOLT, 60 HERTZ, PROCUREMENT OF, SPECIFICATION FOR |
| KSC-SPEC-E-0023 | C | AC POWER CABLE, 15,000 VOLT, 60 HERTZ, PROCUREMENT OF, SPECIFICATION FOR |
| KSC-SPEC-E-0024 | A | CABLE, ELECTRICAL, SHIELDED, JACKETED FOR HARNESS ASSEMBLIES, GENERAL SPECIFICATION FOR |
| KSC-SPEC-E-0029 | BASELINE | COMPOUND, POTTING AND MOLDING, ELASTOMERIC, SPECIFICATION FOR |
| KSC-SPEC-E-0031 | B | CABLES, ELECTRICAL, SPECIFICATION FOR (SUPERSEDES MSFC-SPEC-332E) |
| KSC-SPEC-F-0006 | B | HEAT AND BLAST PROTECTION COATING MATERIALS, SPECIFICATION FOR |
| KSC-SPEC-F-0009 | A | SIGNS AT JFK SPACE CENTER, DESIGN, FABRICATION AND ERECTION OF |
| KSC-SPEC-G-0002 | B | COMPILING CONSTRUCTION COST ESTIMATES |
| KSC-SPEC-G-0003 | BASELINE | GROUND SUPPORT EQUIPMENT COST ESTIMATING |
| KSC-SPEC-P-0012 | BASELINE | REFRACTORY CONCRETE, SPECIFICATION FOR |
| KSC-SPEC-P-0014 | A | GARMENTS USED IN NON-CLEANROOM ENVIRONMENTS FOR HAZARDOUS OPERATIONS, MINIMUM REQUIREMENTS FOR, SPECIFICATION FOR |
| KSC-SPEC-P-0015 | B | GARMENTS USED IN CLEANROOM ENVIRONMENTS FOR HAZARDOUS OPERATIONS, MINIMUM REQUIREMENTS FOR, SPECIFICATION FOR |
| KSC-SPEC-P-0016 | A | MINIMUM REQUIREMENTS FOR GARMENT SNAP FASTENER, SPECIFICATION FOR |
| KSC-SPEC-P-0017 | BASELINE | PROPELLANTS, RECOVERED HYDRAZINE FAMILY FUELS, SPECIFICATION FOR |
| KSC-SPEC-P-0018 | BASELINE | PROPELLANTS, RECOVERED NITROGEN TETROXIDE SOLUTION, SPECIFICATION FOR |
| KSC-SPEC-P-0019 | BASELINE | SOLVENT, CLEANING, 1,1,1,2,3,4,4,5,5,5-DECAFLUOROPENTANE (62 WT%) AND TRANS-1,2-DICHLOROETHYLENE (38 WT%), VERTREL MCA TM, SPECIFICATION FOR |
| KSC-SPEC-P-0020 | BASELINE | SOLVENT, CLEANING, 3,3-DICHLORO-1,1,1,2,2-PENTAFLUOROPROPANE (45+5 WT%) AND 1,3-DICHLORO-1,1,2,2,3-PENTAFLUOROPROPANE (55+5 WT%) HCFC-225, SPECIFICATION FOR |
| KSC-SPEC-P-0021 | BASELINE | SOLVENT, CLEANING, 1,1,1,2,3,4,4,5,5,5-DECAFLUOROPENTANE, SPECIFICATION FOR |
| KSC-SPEC-P-0022 | BASELINE | SOLVENT, CLEANING, 1,3-DICHLORO-1,1,2,2,3-PENTAFLUOROPROPANE, HCFC-225G, SPECIFICATION FOR |
| KSC-SPEC-P-0024 | BASELINE | REFRIGERANT, HCFC-124, 2-CHLORO-1,1,1,2-TETRAFLUOROETHANE, SPECIFICATION FOR |
| KSC-SPEC-P-0025 | BASELINE | PROPYLENE GLYCOL MONOMETHYL ETHER (PGME) 1-METHOXY-2-PROPANOL, SPECIFICATION FOR |
| KSC-SPEC-P-0026 | BASELINE | PROPELLANTS, RECOVERED HALON-1301, SPECIFICATION FOR |
| KSC-SPEC-Z-0001 | A | PIPE, 36% NICKEL, IRON-BASE (INVAR 36), SPECIFICATION FOR |
| KSC-SPEC-Z-0005 | A | BRAZING-STEEL, COPPER, ALUMINUM, NICKEL, AND MAGNESIUM ALLOYS, SPECIFICATION FOR |
| KSC-SPEC-Z-0006 | A | INDUCTION BRAZING, AEROSPACE TUBING FITTINGS, SPECIFICATION FOR |
| KSC-SPEC-Z-0007 | E | TUBING, STEEL, CORROSION RESISTANT, TYPES 304 AND 316, SEAMLESS, ANNEALED, SPECIFICATION FOR |
| KSC-SPEC-Z-0011 | A | SILICONE RUBBER ABLATIVE MATERIAL TO GROUND SUPPORT EQUIPMENT, APPLICATION OF, SPECIFICATION FOR |
| KSC-SPEC-Z-0013 | BASELINE | PENETRANT, MAGNETIC PARTICLE AND ULTRASONIC INSPECTION, REQUIREMENTS FOR, SPECIFICATION FOR |
| KSC-SPEC-Z-0019 | E | AGE CONTROL OF ELASTOMERIC PARTS, SPECIFICATION FOR |
| KSC-STD-132 | D | POTTING AND MOLDING ELECTRICAL CABLE ASSEMBLY TERMINATIONS, STANDARD FOR |
| KSC-STD-141 | A | LOAD TEST IDENTIFICATION AND DATA MARKING, STANDARD FOR |
| KSC-STD-152-1 | C | GRAPHICAL SYMBOLS FOR DRAWINGS. PART 1: FACILITIES, STANDARD FOR |
| KSC-STD-152-2 | C | GRAPHIC SYMBOLS FOR DRAWINGS. PART 2: GROUND SUPPORT EQUIPMENT, STANDARD FOR |
| KSC-STD-164 | B | ENVIRONMENTAL TEST METHODS FOR GROUND SUPPORT EQUIPMENT, STANDARD FOR |
| KSC-STD-6 | D | CARD HOLDER ATTACHMENTS AND ROOM NUMBERS, STANDARD FOR |
| KSC-STD-E-0001 | C | DESIGN OF ELECTRICAL CONTROL AND MONITORING SYSTEMS, EQUIPMENT (GSE), AND PANELS, STANDARD FOR |
| KSC-STD-E-0002 | D | HAZARD PROOFING OF ELECTRICALLY ENERGIZED EQUIPMENT, STANDARD FOR |
| KSC-STD-E-0004 | B | PNEUMATIC AND HYDRAULIC MECHANICAL COMPONENTS, ELECTRICAL DESIGN, STANDARD FOR |
| KSC-STD-E-0006 | B | INSTRUMENTATION AND COMMUNICATIONS CABLE APPLICATIONS, STANDARD FOR |
| KSC-STD-E-0009 | B | CABLE NUMBERING, OUTSIDE PLANT COMMUNICATION SYSTEM, STANDARD FOR |
| KSC-STD-E-0010 | A | SOLDERING OF ELECTRICAL CONNECTIONS, (HAND OR MACHINE), STANDARD FOR |
| KSC-STD-E-0011 | G | ELECTRICAL POWER RECEPTACLES AND PLUGS, STANDARD FOR |
| KSC-STD-E-0012 | E | FACILITY GROUNDING AND LIGHTNING PROTECTION, STANDARD FOR (TITLE CHANGED FROM BONDING AND GROUNDING, STANDARD FOR, BY REVISION D, 6/7/2000) |
| KSC-STD-E-0014 | B | WIRE AND CABLE APPLICATIONS, STANDARD FOR |
| KSC-STD-E-0015 | B, Change 1 | MARKING OF GROUND SUPPORT EQUIPMENT, STANDARD FOR |
| KSC-STD-E-0021 | BASELINE | TELECOMMUNICATION PREMISES DISTRIBUTION SYSTEMS, DESIGN OF, STANDARD FOR (KSC) |
| KSC-STD-F-0004 | E | FIRE PROTECTION DESIGN, STANDARD FOR |
| KSC-STD-F-0004 | E | FIRE PROTECTION DESIGN, STANDARD FOR |
| KSC-STD-G-0003 | B | LAUNCH SUPPORT AND FACILITY COMPONENTS, QUALIFICATION OF, STANDARD FOR |
| KSC-STD-P-0001 | B | EQUIPMENT OF SYSTEM PROCUREMENT/PERFORMANCE SPECIFICATIONS, PREPARATION OF, STANDARD FOR |
| KSC-STD-P-0002 | A | COMPONENT PROCUREMENT/PERFORMANCE SPECIFICATIONS, PREPARATION OF, STANDARD FOR |
| KSC-STD-P-0006 | BASELINE | QUICK RELEASE PINS AND PIN TETHERS, STANDARD FOR |
| KSC-STD-P-0007 | BASELINE | NETBIOS NAMING FOR NETWORKS CENTER DOMAIN, WORKGROUP, WORKSTATION, AND USER REGISTRATION, STANDARD FOR |
| KSC-STD-SF-0004 | B | GROUND PIPING SYSTEMS COLOR CODING AND IDENTIFICATION, SAFETY STANDARD FOR |
| KSC-STD-Z-0006 | B | HYPERGOLIC PROPELLANTS GROUND SUPPORT EQUIPMENT, DESIGN OF, STANDARD FOR |
| KSC-STD-Z-0007 | BASELINE | HYDROCARBON FUEL GROUND SUPPORT EQUIPMENT, DESIGN OF, STANDARD FOR |
| KSC-STD-Z-0008 | C | GROUND LIFE SUPPORT SYSTEMS AND EQUIPMENT, DESIGN OF, STANDARD FOR |
| KSC-STD-Z-0009 | C | CRYOGENIC GROUND SUPPORT EQUIPMENT, DESIGN OF, STANDARD FOR |
| KSC-STD-Z-0010 | A | ENVIRONMENTAL CONTROL SYSTEMS, GROUND COOLANT SYSTEMS, COOLANT SERVICING SYSTEMS AND GROUND SUPPORT EQUIPMENT, DESIGN OF, STANDARD FOR |
| KSC-STD-Z-0012 | B | FLAME DEFLECTOR DESIGN, STANDARD FOR |
| KSC-STD-Z-0013 | BASELINE | POTABLE WATER CROSS-CONNECTION CONTROL DESIGN FOR FACILITIES, STANDARD FOR |
| KSC-W-167 | B | WIRING PROGRAMMING SYSTEM PATCHBOARDS, SPECIFICATION FOR |